คุณสมบัติ
Product characteristics
Electrical design PNP/NPN; (parameterisable)
Output function normally open / normally closed; (parameterisable)
Communication interface IO-Link
Housing threaded type
Dimensions [mm] M8 x 1 / L = 50
Application
Special feature Gold-plated contacts
Electrical data
Operating voltage [V] 10...30 DC
Current consumption [mA] < 15
Protection class III
Reverse polarity protection yes
Outputs
Electrical design PNP/NPN; (parameterisable)
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2.5
Permanent current rating of switching output DC [mA] 100
Switching frequency DC [Hz] 600
Short-circuit protection yes
Overload protection yes
Detection zone
Switch point IO-Link [mm] 0.56...2.8; (parameterisable)
Measuring range IO-Link [mm] 0.3...3
Accuracy / deviations
Correction factor steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.4 / copper: 0.3
Hysteresis [% of Sr] 3...15
Note on hysteresis parameterisable
Linearity error IO-Link [%] ± 3; (of the final value of the measuring range)
Repeatability IO-Link [%] ± 2; (of the final value of the measuring range)
Temperature drift ± 10 %; (of the final value of the measuring range)
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Identification and diagnosis; Multi-channel, two setpoint switching sensor, type 0 Generic Profiled Sensor; Teach Channel
SIO mode yes
Required master port type A
Min. process cycle time [ms] 3.2
IO-Link process data (cyclical) function bit length
process value 16
device status 4
binary switching information 2
IO-Link functions (acyclical) switching cycles counter; switch-on cycle counter; operating hours counter; internal temperature; application specific tag
Supported DeviceIDs Type of operation DeviceID
default 1274
Note For further information please see the IODD PDF file under "Downloads"
Operating conditions
Ambient temperature [°C] -40...75
Protection IP 65; IP 66; IP 67; IP 68; IP 69K; (with ifm socket duly screwed on)