คุณสมบัติ
Product characteristics
Electrical design PNP
Output function normally open / normally closed; (selectable)
Sensing range [mm] 12
Communication interface IO-Link
Housing rectangular
Dimensions [mm] 20 x 14 x 48
Application
Installation detection through non-metallic container wall or on bypass pipes
Media dry bulk material; liquids
Electrical data
Operating voltage [V] 10...30 DC
Current consumption [mA] < 17
Protection class III
Reverse polarity protection yes
Measuring principle capacitive
Outputs
Electrical design PNP
Output function normally open / normally closed; (selectable)
Max. voltage drop switching output DC [V] 2.5
Permanent current rating of switching output DC [mA] 100
Switching frequency DC [Hz] 10
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Detection zone
Sensing range [mm] 12
Real sensing range Sr [mm] 12 ± 10 %
Accuracy / deviations
Hysteresis [% of Sr] 1...15
Switch point drift [% of Sr] -20...20
Interfaces
Communication interface IO-Link
Transmission type COM1 (4,8 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9 CDV
Profiles Smart Sensor
SIO mode yes
Min. process cycle time [ms] 100.8
Supported DeviceIDs Type of operation DeviceID
default 371
Operating conditions
Ambient temperature [°C] -25...80
Protection IP 65; IP 67; IP 69K