Magnetic-inductive flow meter

SMF320

Option name 1
จำนวน
รายละเอียดสินค้า

คุณสมบัติ

Product characteristics
Measuring range                        5...750 l/min     300...45000 l/h      0.07...10 m/s     0.3...45 m³/h
Nominal diameter                       DN40 (1 1/2)
Process connection                    ifm-specific device flange

Application
Special feature                           Gold-plated contacts
Application                                food and beverage industry
Media                                       conductive liquids; water; hydrous media
Note on media                           food products such as beer, milk, fruit juices, soft drinks, ketchup, yoghurt, yoghurt toppings, ice cream
conductivity: 5 µS/cm
Medium temperature [°C]             -20...150
Min. bursting pressure                 60 bar            6 MPa
Pressure rating                          40 bar            4 MPa

Electrical data
Operating voltage [V]                  18...32 DC
Current consumption [mA]            250; (24V)
Protection class                          III
Reverse polarity protection           yes
Power-on delay time [s]                < 5
Measuring principle                     magnetic-inductive

Inputs / outputs
Total number of inputs and outputs     2

Inputs
Inputs                                      OUT2             external totaliser reset
Outputs
Total number of outputs              2

Output signal                           OUT               1pulse signal; totaliser switching signal; diagnostic signal; IO-Link                          OUT2              analogue signal; pulse signal; totaliser switching signal; diagnostic signal
Electrical design                       PNP/NPN
Pulse output                            flow rate meter
Short-circuit protection              yes
Type of short-circuit protection   pulsed
Overload protection                  yes

Analogue
Number of analogue outputs       1
Analogue current output [mA]     4...20; (skalierbar)
Max. load [Ω]                            500
Resolution of analogue output     0.38 µA

Digital
Number of digital outputs                                           2
Max. voltage drop switching output DC [V]                     2
Permanent current rating of switching output DC [mA]      100
Switching frequency DC [Hz]                                        0...10000

Measuring/setting range
Measuring range                      5...750 l/min       300...45000 l/h        0.07...10 m/s       0.3...45 m³/h
Display range                         -900...900 l/min   -54000...54000 l/h   -12...12 m/s         -54...54 m³/h
Resolution                              0.01 l/min           50 l/h                   0.01 m/s            0.05 m³/h
Note on factory setting             0...11,0 m³/h
Analogue start point ASP          0...600 l/min        0...36000 l/h           0...7.95 m/s        0...36 m³/h
Analogue end point AEP          150...750 l/min       9000...45000 l/h     2...9.95 m/s         9...45 m³/h
Low flow cut-off LFC                0...600 l/min        0...36000 l/h           0...7.95 m/s        0...36 m³/h
Pulse length [s]                       0.002...2
Pulse value                            0.002...99990000 I

Temperature monitoring
Measuring range [°C]               -20...150
Display range [°C]                   -20...150
Resolution [°C]                        0.01
Analogue start point [°C]          -20...116
Analogue end point [°C]           14...150

Conductivity monitoring
Measuring range [µS/cm]          100...100000
Display range [µS/cm]              0...10000000
Resolution [µS/cm]                   1
Analogue start point [µS/cm]     0...80000
Analogue end point [µS/cm]      20000...100000

Accuracy / deviations
Volumetric flow monitoring        Accuracy (in the measuring range)
with optional factory calibration (available from 2025)          ± (0,2 % MW + 2 mm/s)
standard                                ± (0,5 % MW + 1,5 mm/s)
Repeatability                          0,1% MW

Temperature monitoring
Accuracy [K]                           ± 1
Repeatability [K]                      ± 0,5

Conductivity monitoring
Accuracy (in the measuring range)     in the range of 100...20000 µS/cm        ±10% MW
                                                  in the range of 20000...100000 µS/cm   ±20% MW
Repeatability                          ± 5% MW

Response times
Volumetric flow monitoring
Response time [s]                         < 0.3
Damping process value dAP [s]       0...5

Temperature monitoring
Response time [s]                        < 3; (flow velocity: 0,5m/s)

Conductivity monitoring
Response time [s]                        < 2

Software / programming
Diagnostic functions                    direction of flow detection; liquid detection

Interfaces
Communication interface              IO-Link
Transmission type                       COM3 (230,4 kBaud)
IO-Link revision                          1.1.3
SDCI standard                            IEC 61131-9
Profiles                                     Function class                      Designation
                                              0x4000                              Identification and Diagnosis
                                              0x001                                 BMeasuring and Switching Sensor, floating point, 4 channel
SIO mode                                 yes
Required master port type           A
Process data analogue                6
Process data binary                    8
Min. process cycle time [ms]         1.9
IO-Link process data (cyclical)      functionbit                          length
                                             totaliser                              32
                                             flow                                   32
                                             temperature                        32
                                             conductivity                        32
                                             status                                 4
                                             binary switching information   8
IO-Link functions (acyclical)         direction of flow detection; totaliser; Speicher; operating hours counter; internal temperature; simulation function
Supported DeviceIDs                 Type of operation                 DeviceID
                                             default                               1789

Operating conditions
Ambient temperature [°C]           -20...65
Storage temperature [°C]            -25...80
Protection                                IP 67; IP 69