Magnetic-inductive flow meter

SMF420

Option name 1
จำนวน
รายละเอียดสินค้า

คุณสมบัติ

Product characteristics
Measuring range                  10...1200 l/min        600...72000 l/h        0.09...10 m/s      0.6...72 m³/h
Nominal diameter                 DN50 (2)
Process connection              ifm-specific device flange

Application
Special feature                    Gold-plated contacts
Application                         food and beverage industry
Media                                conductive liquids; water; hydrous media
Note on media                    food products such as beer, milk, fruit juices, soft drinks, ketchup, yoghurt, yoghurt toppings, ice cream
                                       conductivity: 5 µS/cm
Medium temperature [°C]      -20...150
Min. bursting pressure          37.5 bar            3.75 MPa
Pressure rating                   25 bar              2.5 MPa

Electrical data
Operating voltage [V]           18...32 DC
Current consumption [mA]     250; (24V)
Protection class                   III
Reverse polarity protection    yes
Power-on delay time [s]        < 5

Measuring principle
magnetic-inductive              Inputs / outputs
Total number of inputs and outputs     2

Inputs
Inputs                               OUT2               external totaliser reset
Outputs
Total number of outputs        2
Output signal                     OUT1                pulse signal; totaliser switching signal; diagnostic signal; IO-Link
                                      OUT2                analogue signal; pulse signal; totaliser switching signal; diagnostic signal
Electrical design                 PNP/NPN
Pulse output                      flow rate meter
Short-circuit protection        yes
Type of short-circuit protection     pulsed
Overload protection                    yes

Analogue
Number of analogue outputs        1
Analogue current output [mA]      4...20; (skalierbar)
Max. load [Ω]                             500
Resolution of analogue output      0.38 µA

Digital
Number of digital outputs                                           2
Max. voltage drop switching output DC [V]                     2
Permanent current rating of switching output DC [mA]      100
Switching frequency DC [Hz]                                        0...10000

Measuring/setting range
Measuring range                       10...1200 l/min       600...72000 l/h      0.09...10 m/s     0.6...72 m³/h
Display range                          -1440...1440 l/min   -86400...86400 l/h  -12...12 m/s       -86.4...86.4 m³/h
Resolution                               0.1 l/min               50 l/h                  0.01 m/s          0.05 m³/h
Note on factory setting              0...18,0 m³/h
Analogue start point ASP           0...960 l/min          0...57600 l/h          0...8.19 m/s       0...57.6 m³/h
Analogue end point AEP            240...1200 l/min     14400...72000 l/h    2...10.19 m/s      14.4...72 m³/h
Low flow cut-off LFC                 0...960 l/min          0...57600 l/h          0...8.19 m/s       0...57.6 m³/h
Pulse length [s]                        0.002...2

Pulse value                             0.002...99990000 I
Temperature monitoring
Measuring range [°C]                -20...150
Display range [°C]                    -20...150
Resolution [°C]                         0.01
Analogue start point [°C]           -20...116
Analogue end point [°C]            14...150

Conductivity monitoring
Measuring range [µS/cm]           100...100000
Display range [µS/cm]               0...10000000
Resolution [µS/cm]                    1
Analogue start point [µS/cm]      0...80000
Analogue end point [µS/cm]       20000...100000

Accuracy / deviations
Volumetric flow monitoring
Accuracy (in the measuring range)    with optional factory calibration (available from 2025)     ± (0,2 % MW + 2 mm/s)
                                                 standard                                                                ± (0,5 % MW + 1,5 mm/s)
Repeatability                          0,1% MW

Temperature monitoring
Accuracy [K]                           ± 1
Repeatability [K]                      ± 0,5

Conductivity monitoring
Accuracy (in the measuring range)     in the range of 100...20000 µS/cm             ±10% MW
                                                   in the range of 20000...100000 µS/cm       ±20% MW
Repeatability                                  ± 5% MW

Response times
Volumetric flow monitoring
Response time [s]                           < 0.3
Damping process value dAP [s]         0...5

Temperature monitoring
Response time [s]                    < 3; (flow velocity: 0,5m/s)

Conductivity monitoring
Response time [s]                    < 2

Software / programming
Diagnostic functions                 direction of flow detection; liquid detection

Interfaces
Communication interface          IO-Link
Transmission type                   COM3 (230,4 kBaud)
IO-Link revision                      1.1.3
SDCI standard                        IEC 61131-9
Profiles                                 Function class             Designation
                                          0x4000                     Identification and Diagnosis
                                          0x001                        BMeasuring and Switching Sensor, floating point, 4 channel
SIO mode                             yes
Required master port type       A
Process data analogue            6
Process data binary                8
Min. process cycle time [ms]     1.9
IO-Link process data (cyclical)   function                              bit length
                                          totaliser                              32
                                          flow                                   32
                                          temperature                        32
                                          conductivity                        32
                                          status                                  4
                                          binary switching information    8
IO-Link functions (acyclical)      direction of flow detection; totaliser; Speicher; operating hours counter; internal temperature; simulation function
Supported DeviceIDs              Type of operation                  DeviceID
                                          default                                1639

Operating conditions
Ambient temperature [°C]        -20...65
Storage temperature [°C]         -20...80
Protection                            IP 67; IP 69